A&D MOISTURE ANALYSER (51g x 0.005g)
Description
· Fast and uniform heating with halogen lamp and innovative SRA technology - Straight halogen lamp and uniquely designed SRA (Secondary Radiation Assist) filter gives shorter measurement time, thanks to fast and uniform heating
· High repeatability - With Super Hybrid Sensor (SHS) featured as the weight sensor, ultra accurate moisture content determination is possible based on high precision weighing of even a small sample
· Low moisture content measurement - MS-70 measures the moisture content at 0.001% resolution suitable for low moisture content samples as well as Karl Fischer method, yet requires no special knowledge or training and produces no harmful waste
· WinCT-Moisture (for MS&MX) for real-time graph displaying - WinCT-Moisture is an original software application designed to display a graph of moisture content rate change while measuring with a connected PC
· Sodium Tartrate Dihydrate comes as standard for accuracy checking - Sodium Tartrate Dihydrate is a chemical material that has stable moisture content of 15.66% , and thus is best to use for accuracy check to maintain the reference value of the analyzer
· Calibration of the heater temperature (for MS&MX) +0.3-0.1 With the temperature calibrator (optional), calibration result can be output in the format that conforms to GLP, GMP, ISO
· Memory function - According to sample up to 20 suitable measurement conditions can be stored and recalled, which saves time and prevents the user from making a mistake when setting (10 for MF & 5 for ML) For measurement result, up to 100 data can be stored and output at once (50 for MF & 30 for ML)
· Five measurement programs - Five choices of measurement programs, Standard, Automatic, Quick, Timer, and Manual Mode are provided Standard Mode : Just measurement accuracy, HI, MID or LO needs to be set Automatic Mode : Ends measurement when moisture content changes at a rate less than the set rate Quick Mode : Begins heating samples at 200°C for 3 minutes, then is the same as Automatic Mode Timer Mode : Continues measurement for a set duration of time (1~60mins.: by 1min, 60~480mins.: by 5mins.) Manual Mode : STOP button should be pressed to end measurement (Max. heating time: 480mins.)
· Selectable Heating Mode - Choose the heating mode from standard, quick, step and ramp heating modes for the most suitable measurement (ML has Standard and Quick heating modes only)
· Clear and easy-to-see, large VFD display - Measurement, setting value, change in moisture content, action status, data number and other important information are clearly displayed
· Easy handling of the unit - Ergonomically designed pan handle eliminates mishaps such as burns when moving a hot sample pan into or out of the unit from either side. Wing handle for easy opening and closing of the heater cover
· Low maintenance cost assured - The halogen lamp is user replaceable without unit downtime with protective chamber for easy cleaning (Lamp life 5000 hours)